Motorola MTP3150

Manufacturer Motorola
Model MTP3150
Release year 2020
Firmare version 14.2
Tested CPS versions CPS Plus 8.1

Battery replacement

The original part code for the original battery is NNTN8023B.

You can find working replacements fairly easily on Aliexpress, for instance:

From what I've seen, MTP3XXX batteries should be compatible with this device.

Creating a backup of the device

Before doing anything with the device, it is recommended to fully back it up. Doing so is easy:

  1. Plug radio and enter programming mode
  2. On the top of the software, click on "Lab" then "Flash report"
  3. In the window, click on "Flash image filename" and name your backup
  4. Set "Report type" to "Entire flash"
  5. Select your radio on the left
  6. Click on "Start operation"

This might take a while, but you will be left with a full backup of your device afterwards.

Enabling features

Some features are locked behind a license, but can be force-enabled via the Lab mode of the CPS software. To do so:

  1. Enter lab mode by doing CTRL+L or going on top to "Lab" then "Lab mode"
  2. Within cp_all_t tree:
    1. Locate and expand cp_sale_feature_t
    2. Click on sale_feature_data
    3. Set "Field Value" to 0x01 (or 01 depending on display) for features that you want to enable
  3. When you are finished, disable lab mode
  4. You can now write the full codeplug to the device

Using the right frequency

By default, TETRA uses a radio band outside of the regular amateur bands.

Luckily, we can force the radio to transmit on the 70cm ham band via the lab mode.

  1. Enter lab mode by doing CTRL+L or going on top to "Lab" then "Lab mode"
  2. Within cp_all_t tree:
    1. Locate and expand cp_hwconst_block
    2. Within it, locate and expand hwconst_data
    3. Now find and expand freq_valid_range[]
    4. Select freq_valid_range[0]
    5. You can now set the following values:
      • min_freq to 0x14DC9380 (350000000Hz, should be default) For Finland, correct value is 0x19bfcc00 (432000000Hz)
      • max_freq to 0x1AD27480 (450000000Hz, example, use your local limit for 70cm band) For Finland, correct value is 0x1a1b5980 (438000000Hz)
    6. Within the main tree, locate cp_net_block and expand it
    7. Within it, expand net_data
    8. Expand TMO_range_table[] and within it:
      1. Select TMO_range_table[0]
      2. Set min_rx_freq and max_rx_freq to the same values as before
  3. You can now write the full codeplug to the device

Enabling encryption

You don't.